advertisement>
Put your website to work earning real money!
Item: 908
Micropolis 1355 ESDI




               Micropolis 1350 Series Disk Drives
                          SPECIFICATIONS

                                      Model Number
Unformatted Capacity    1353     1353A     1354    1354A     1355

  Total Mbytes          85.3     106.6    127.9    149.3    170.6
  Disk Platters            3         3        4        4        5
  Read/Write Heads         4         5        6        7        8
  Cylinders             ------------------ 1024 -----------------
  Bytes per track       ---------------- 20,832 -----------------

Formatted Capacity

  Total Mbytes          75.4     94.2     113.1    131.9    150.8
  Bytes per Sector      ------------------- 512 -----------------
  Sectors per Track     -------------------- 36 -----------------

PC Drive Types

  If you are using third-party installation software or an on-board
  BIOS on the controller, follow the instructions included with the
  software or controller. Otherwise, examine the entries in your
  drive table and find the type that most resembles the head and
  cylinder parameters of the drive without exceeding these
  parameters.

Performance Specifications

  Seek Time (including settling time)     Track-to-Track   5 msec
                                          Average         23 msec
                                          Maximum         50 msec
  Average Rotational Latency                            8.33 msec
  Rotational Speed                              3600 rpm +/- 0.5%
  Data Transfer Rate                                 10 Mbits/sec
  MTBF                                              150,000 hours
  Positioner                     Fully balanced rotary voice coil
  Parking                                 Automatic park and lock

General Functional Specifications

  Interface                                                  ESDI
  Sectoring (see W1 description below)               Hard or Soft
  Write Precompensation Start Cylinder                      1024*
  Reduced Write Current Start Cylinder                      1024*
  Landing Zone                                               1024
  Mounting Plane                                  Any orientation

  * These are effectively turned off by specifying a non-existent
  cylinder. Some systems accomplish this by using a value of "-1"

Power Requirements

  +12V +/-5%                                             2.0A avg
                                      (4.25A max during start-up)
  +5V +/-5%                                              2.0A avg
  Power dissipation, typical                             32 Watts

Drive Addressing and Interface Termination
                                               NOT
                 J1                  J2        USED
   ___   __________________     ____________   ___   ___
  |   | |1|                |   |1|          | |   | |   |
  |   |_|                  |___|            |_|   |_|   |
  |                      D D D                          |
  |     TERMINATOR       A A A W W W W W                |
  |                      3 2 1 5 4 3 2 1                |
  |                                                     |
  |                                                     |
  |                (COMPONENT SIDE)                     |

RN1 Interface Terminator
  The Interface Terminator factory installed at RN1 provides proper
  termination for the interface lines. When daisy-chaining multiple
  drives, leave the terminator installed only in the last physical
  drive on the daisy chain cable; remove the terminator from each
  of the other drives. In most PC/AT installations, the C: drive
  is actually at the end of the cable and should retain the
  terminator.

DA1, DA2, DA3 Drive Select Jumpers
  The Drive Address jumpers are identified as DA1, DA2, and DA3.
  Address selection is binary, as shown in the table below. The
  ESDI controller's documentation will specify the drive address
  to use.

   Drive           Select Jumpers
  Address        DA3     DA2     DA1
  -------        ---     ---     ---
     1           out     out      in
     2           out      in     out
     3           out      in      in
     4            in     out     out
     5            in     out      in
     6            in      in     out
     7            in      in      in

  "Drive Address 0" (no jumper at DA1, DA2 or DA3) is a "deselect"
  (i.e., no drive selected). For many multiple drive installations,
  each drive must have a unique address. An exception is that for
  every drive in a PC/AT installation, verify that the only Drive
  Address jumper is at DA2; move the jumper if necessary (the
  special twisted interface cable that is generally used takes care
  of assigning a unique address to each drive). PC/AT controllers
  can typically support a maximum of two drives.

W5 Select the Spindle Control Option
  W5 selects the spindle control option. If W5 is installed, the
  drive waits for a Start Spindle command (after power is applied)
  to start the spindle motor. If W5 is not installed (the factory
  default configuration), the drive automatically starts the
  spindle motor at power-on. W5 is not installed for PC/AT
  installations.

W1 Selects the Sectoring Mode.
  If W1 is installed, the drive operates in the soft-sectored mode.
  If W1 is not installed (the factory default configuration), the
  drive operates in the hard-sector mode. W1 is not installed for 
  most PC/AT applications.

W2, W3, W4 Sector Size Option
  The number of bytes per sector may be specified using the Set
  Bytes Per Sector command or by selecting a default sector 
  configuration with jumpers W2, W3, and W4 as follows:

       Jumpers            Sectors            Bytes/Sector
    W4    W3    W2       Per Track       Formatted  Unformatted
    ---   ---   ---      ---------       ---------  -----------
    out   out   out         35              512          595
 -------------------------------------------------------------
| * out   out    in         36              512          578  |
 -------------------------------------------------------------
    out    in   out         19             1024         1096
    out    in    in          9             2048         2314
     in   out   out          5             4096         4166
     in   out    in         32              512          651
     in    in   out         64              256          325
     in    in    in          1           20,832       20,832

  * This is the default (factory installed) configuration and is
  recommended for PC/AT applications