Support Home Page
Cubix Home Page
Feedback Forms

Appendix A
SafeStor/FT II Specifications


Architecture

Passive SCSI Backplane 12 Disk Connectors
2 x 6 2 groups of 6 connectors Active Termination
3 x 4 3 groups of 4 connectors Active Termination
1 x 12: 1 group of 12 connectors Active Termination
Slot Spacing 1.28"
Third-Height Carrier Width 1.23"
Half-Height Carrier Width 2.51"
Carrier Height 4.59"
Carrier Length 12.49"
5.25" Carrier Width 7.63"
Bus Speed 10 MHz

Configurations

Groups Half-Height Drives Third-Height Drives
Two 3+3 6+6
One 6 12
Three 2+2+2 4+4+4
  • F 3.5" third-height and half-height, and 5.25" half-height and full-height drives
    may be combined into a single SafeStor-FT II.
  • Drive Accommodations

    Maximum Third-height 3.5" Hard Drives 12

    or

    Maximum Half-height 3.5" Hard Drives 6

    or

    Maximum Half-height 5.25" Drives 4

    or

    Maximum Full-height 5.25" Drives 2

    Mechanical

    Rack Mount Enclosure Standard 19" RETMA
    Faceplate Dimensions 19" wide x 8.60" high
    Enclosure Dimensions 17.50" wide x 8" high x 18" deep

    Security

    Key-lock for Each Disk Drive Yes
    Key-lock for PCM Yes
    Key-lock for Each Power Supply Yes
    Key-lock for Optional IES Yes

    Diagnostics

    Drive Module Power Indicators Yes
    Disk Activity Indicators Yes
    Alarm Speaker Off Push-button Optional
    Dual Power Supply On-line & Fault Indicators Yes
    Fan On-line & Fault Indicator Optional
    Data Highway On-line & Fault Indicator Optional
    Subsystem Health Indicator Optional
    Environmental Alert Indicator Optional

    Rear Panel Connections

    Power Supply 1 (PS1):
    .. Receptacle IEC 320, 10a, male pins
    .. On/Off Switch Yes
    .. AC Power On Indicator Yes
    Power Supply 2 (PS2):
    .. Receptacle IEC 320, 10a, male pins
    .. On/Off Switch Yes
    .. AC Power On Indicator Yes
    SCSI I/O Connectors (50 or 68 pin) 1 per group
    IES I/O Connectors Dual RJ-11

    Power Supply

    Ratings
    +5vdc 10 amps
    +12vdc (steady state) 10 amps
    +12vdc (Peak) 30 amps
    Maximum DC Power 170 watts (steady state)
    383 watts (peak)

    Input Power Ratings

    115 VAC ± 15% 3 amps
    240 VAC ± 15% 1.5 amps

    Operating Environment

    Temperature
    (measured at each of 4 fan inlets)
    0 - 40 C
    Non-Condensing Humidity 5 - 80%

    Heat Exhaust Fans

    Power Supply (each) one 60mm, 19 CFM
    Rear Panel two 80mm, 44 CFM Hot Swappable

    Warranty

    Parts and labor return-to-manufacturer 1 year

    Compliance

    FCC Class A

    This document, and all Web contents, Copyright © 1997 by Cubix Corp., Carson City, NV, USA.